When you run RSLogix Emulate software, you can place your computer on a simulated DH485 (for SLC 500 emulation) or DF1 (for PLC-5 emulation) network, connecting it with a computer running operator interface software such as RSView. With this setup, you can test your operator interface before connecting it to a physical processor. (If you want to simulate using Channel 0 with ASCII devices, see the Channel 0 emulation topic.)
To use Data Highway 485/DF1 emulation:
- Set the station number for your project to 1. To do this, click Settings > Emulation, then set the Station # field to 1. (The DF1 or DH 485 emulation will not work unless the station number is set to 1.)
- Connect a serial cable (a straight-through cable) to connect one of your computer's serial ports (COM ports) to a COM port on the computer running the operator interface software.
- In RSLogix Emulate, click Settings > Channel 0 Data Highway. The software displays a dialog allowing you to set up a COM port to simulate communications.
- From the Port listbox, select the COM port you want to use. (Make sure the COM port you choose is not occupied by another device, such as a mouse.)
- From the Baud listbox, select the communication speed for your connection. You should select the same speed as the connection between the operator interface computer and the physical processor.
- From the Parity listbox, select the parity for the connection. You should use the same parity as the connection between the operator interface computer and the physical processor.